IMC告警收到不可解析的OSPF报文解决办法
故障设备:核心S12518,汇聚S10508-V
故障现象:IMC告警提示“接口收到不可解析的OSPF报文,S12518 _IP为X.X.X.X的接口收
到从X.X.X.X发过来的报文类型为1的误配置信息。”
故障诊断:经过两台设互PING得出以下结果
PING X.X.0.1: 56 data bytes, press CTRL_C to break
Reply from X.X.0.1: bytes=56 Sequence=1 ttl=255 time=1 ms
Reply from X.X.0.1: bytes=56 Sequence=1 ttl=255 time=202 ms (DUP!)
Reply from X.X.0.1: bytes=56 Sequence=2 ttl=255 time=2 ms
Reply from X.X.0.1: bytes=56 Sequence=2 ttl=255 time=202 ms (DUP!)
Reply from X.X.0.1: bytes=56 Sequence=3 ttl=255 time=1 ms
Reply from X.X.0.1: bytes=56 Sequence=3 ttl=255 time=202 ms (DUP!)
Reply from X.X.0.1: bytes=56 Sequence=4 ttl=255 time=1 ms
Reply from X.X.0.1: bytes=56 Sequence=4 ttl=255 time=202 ms (DUP!)
Reply from X.X.0.1: bytes=56 Sequence=5 ttl=255 time=1 ms
--- X.X.0.1 ping statistics ---
5 packet(s) transmitted
9 packet(s) received
4 duplicates
0.00% packet loss
round-trip min/avg/max = 1/62/202 ms
解决办法:根据以上PING 信息可能看出在这台交换机上存在重复报文(DUP!为重复报文)检查配置在设备上配置了端口镜像,发现端口镜像镜像到了上联出口所以造成了重复的报文。经过修改后问题解决。
问题根源:由于用户的误配置将镜像做到了上联口导致故障发生,此情况应该将数据镜像到Netstram插卡的内连接口为正确。